The problem of unbalanced load is something that is difficult to avoid in low voltage distribution networks even though the three-phase installation network is attempted with a balanced load distribution.... Unbalanced loads still occur because of the life and death of electrical appliances that alternate according to needs and things that are detrimental because in unbalanced loads flow neutral currents that cause power losses. In this study the authors examined two distribution transformers of 500 kVA each that supply the distribution network and low voltage installations in the cargo terminal building of Juanda Airport Surabaya. Ketentuyan on IEEE 446-1995 unbalanced load allowed is less than 20%, and after measurements, calculations and analysis on transformer number 01 cargo terminal with loading 27.73% - 28% there is no load development is still below 20% with efficiency 91, 06% - 96.5%, but on transformer number 02 with loading 10.58 5% - 12.14% there is an unbalanced load of 20% - 25.66% with efficiency 85.09% - 94.57%.


 

Keywords

Efisiensi Power Loss Neutral Current Unbalanced Load

Article Details

How to Cite
Hartono, H., Hariyadi, S. ., Indrianto Sudjoko, R. ., Sukomardojo, T. ., Julaihah, S. ., & Ximenes Guterres, J. . (2024). Pengaruh Beban Tidak Seimbang terhadap Efisensi Transformator Daya2 X 500 KVA di Terminal Kargo Bandara Juanda Surabaya. Jurnal Penelitian, 9(2), 137–148. https://doi.org/10.46491/jp.v9i2.1840

References

  1. Abdul Kadir. (1989). Transformator. Jakarta: P.T. Elex Media Komputindo.
  2. Abdul Kadir. (2000). Distribusi dan Utilisasi Tenaga Listrik. Jakarta: UI Press.
  3. B.L. Theraja, & A.K. Theraja. (1995). A Text Book of Electrical Technology (Vol. II, AC & DC Machines). Nirja Construction & Development Co. (P) Ltd.
  4. Burke, J. J. (1994). Power Distribution Engineering -Fundamentals and Applications. New York: Marcel-Dekker Inc.
  5. Hamles, L. L. (2018). Analisa Umur Pakai Transformator Distribusi 20KV di PT. PLN Cabang Ambon. Jurnal Simetrik, 8(2), 126–132.
  6. IEEE. (1995). Recommended Practice for Emergency and Standby Power System for Industrial and Commercial Applications. IEEE.
  7. Mharakurwa, E. T., Nyakoe, G. N., & Akumu, A. O. (2018). Thermal Modelling of Power Transformer with Unbalanced Loading. Pan African University Institute for Basic Science and Technology (PAUSTI), IEEE Press. https://doi.org/10.1109/PowerAfrica.2018.8521168
  8. Muhammad, S. (2020). Analisis Perkiraan Umur Transformator Distribusi Berdasarkan Susut Umur Pada Penyulang F5-Bukit Intan Kota Pangkalpinang. Skripsi. Universitas Bangka Belitung.
  9. Parlindungan, G. (2017). Studi Susut Umur Transformator Distribusi 20KV Akibat Pembebanan Lebih di PT. PLN (Persero) Kota Pontianak. Jurnal Teknik Elektro Universitas Tanjungpura, 2.
  10. Saputro, A. E. Y., & Agus, S. (2018). Analisis Pengaruh Ketidakseimbangan Beban Terhadap Efisiensi Transformator Distribusi di PT. PLN (Persero) Rayon Palur Karanganyar. Skripsi. Universitas Muhammadiyah Surakarta.
  11. Sardono, S., Semin, & Hanif, M. (2017). Analysis of Unbalanced Load of Three Phase Transformer Feedback 61-103 Performance of The Various Connection Winding. Proceeding of The International Conference on Advanced Mechatronics, Intelligent Manufacture, and Industrial Automation (ICAMIMIA), IEEE Press. https://doi.org/10.1109/ICAMIMIA.2017.838575

Most read articles by the same author(s)

<< < 1 2 3 > >>